Alarm Systems
Security/fire
alarm systems protect the assets of
your organization, lower your
insurance rates, and often increase
the confidence your clients have in
your business. However, value added
features and flexibility are both
key to maximizing your investment
and taking full advantage of your
monitoring system. The
award-winning DSC MAXSYS System has
set new standards in the industry,
for both features and flexibility,
that will be emulated for years to
come.
| |
|
| |
Communications...an
extensive range of
options!
- Digital
- Cellular
- Long Range
Radio
- Event
Initiated Paging
|
|
|
| |
|
PC4010
/
PC4020...
Expandability
that's built-in for
installation
flexibility and
economy!
Start with 8 or 16
zones and expand to
64 or 128 by
choosing the best
combination of
technologies to suit
the job at hand:
COMBUS expansion…
add zone input
modules right up to
64 or 128 zones, as
well as a host of
other output
modules, relay
modules, etc… all on
a 4-conductor
non-shielded station
wire bus.
ADDRESSABLE LOOP
expansion…
built right onto the
main panel,
addressable loops
make zone expansion
simple using DSC
addressable devices.
Add 56 or 112
addressable devices
for panel expansion
to full capacity of
64 or 128 zones.
WIRELESS
expansion…
makes filling the
gap where hardwiring
is difficult,
disruptive, or cost
prohibitive as easy
as connecting a
MAXSYS 64 zone
wireless receiver to
the COMBUS and
choosing from an
array of DSC
wireless components
including PIRs, door
contact modules,
smoke detectors,
emergency pendants,
and for flexibility
of control – 4
button key fobs and
handheld keypads. |
|
|
|
|
| |
|
LOADED
WITH
FEATURES
"RIGHT
OUT
OF
THE
BOX" |
|
· |
4 or
8
system
partitions |
|
· |
1,000
user
codes |
|
· |
3,000
event
buffer |
|
· |
30
programmable
zone
types |
|
· |
59
programmable
output
options |
|
· |
local
and
remote
upload/download |
|
· |
99
date
schedules |
|
· |
50
arm/
disarm
schedules |
|
· |
99
open/
close
suppression
schedules |
|
· |
two-year
holiday
scheduling |
|
· |
automatic
daylight
savings
adjustment |
|
· |
add
up
to
16
LCD
keypads |
|
· |
add
up
to
64
programmable
relays |
|
· |
add
up
to
144
low
power
outputs |
|
· |
add
point/graphic
annunciation |
|
· |
UL &
ULC
listed
for
:
· residential
· commercial
applications |
|
· |
And
much
more… |
|
|
|
|
|
|
|
 |
|
|
|
|
COMBUS... input zone
modules, low power outputs,
programmable relays, access
control modules, remote
annunciators all connected
to the main panel via a
4-wire, #22 AWG non-shielded
cable. With input/output
modules located remotely -
on up to 4 runs of 1,000
feet (305m) each - home-run
wiring is eliminated and the
installation is simplified
for the installer. |
|
|
|
|
|
 |
| |
|
Plain
Language Keypads...
What could be
more user-friendly!
Take the mystery out
of security system
operation with up to
16 easy to read 32
character LCD
keypads, each with
five programmable
function keys to
make regular
operations a snap.
Connected to the
COMBUS, keypads can
be assigned for
global or partition
usage. |
| |
|
|
|
Addressable
Loops...
Make
expansion
easy
and
economical!
Right
out
of
the
box
–
ready
to
go –
no
modules
to
add
–
expand
the
system
to
full
zone
capacity
with
2-wire
addressable
loops
built
right
onto
the
main
panel.
Addressable
loops
reduce
costs
through
minimum
module
and
wire
usage…
for
maximum
installation
efficiency
and
economy! |
|
|
|
Addressable
Devices...
| AMA-100 |
- |
Glassbreak detector |
| AMB-300 |
- |
PIR motion detector |
| AMB-500 |
- |
Ceiling mount PIR motion detector |
| AMB-600 |
- |
Pet-immune PIR motion detector |
| AMP-700 |
- |
Door/ window contact |
| AMP-701 |
- |
Point module – 3 NC inputs |
| AMS-220 |
- |
Photoelectric smoke detector |
| AMS-220T |
- |
Photoelectric smoke detector
w/ 135° heat detector |
| |
|
| |
|
|
|
|
|
|
 |
| |
|
Remote Zone
Expanders...
Flexibility at
hand!
Need to add 8 zones
here, 16 zones
there? Go right
ahead with MAXSYS
remote zone
expanders. Simply
connect them to the
COMBUS for flexible,
efficient,
distributed zone
expansion. |
| |
 |
| |
|
Wireless Expansion...
Convenience
and protection!
For those hard to
wire locations, add
up to 64 wireless
zones; and for
personal protection
and operating
convenience add up
to 64 emergency
pendants, 16 key
fobs, and 4 handheld
keypads using DSC's
proven 900MHz true
spread spectrum
wireless technology. |
| |
| |
|
|
Remote
Annunciation...
Information
in
plain
sight!
DSC's
unique
point
or
graphical
annunciators
can
display
up
to
144
zone,
partition,
and
system
events,
providing
critical
information
for
operating
and
emergency
service
personnel.
Easy
to
install,
with
just
4
wires
to
the
COMBUS
the
PC4632/PC4664,
32/64
point
annunciators
provide
direct
system
status
and
can
be
flush-mounted
for
an
attractive
installation. |
|
|
|
|
|
 |
|
|
|
|
|
|
| |
|
| |
|

PC4701 Fire Module...
With the 2
supervised
communicator outputs
critical to all
commercial fire
alarm systems, the
PC4701 included with
the main control
panel also provides
smoke detector and
water flow zones, as
well as fire
alarm-actuated and
fire
trouble-actuated
output relays. |
| |
|

PC4204CF Quad Relay
& Power Supply Panel...
Packaged in an
enclosure with
transformer and
battery charger to
meet UL864
requirements, the
PC4204CF is the fire
version of the
PC4204 for security
systems. Each
PC4204(CF) provides
added power for the
COMBUS plus 4 high
current relays. With
up to 16 PC4204(CF)
modules, the system
can include a total
of 64 fully
programmable relays. |
| |
|
|
|
|
|
 |
Fire
Zone
Annunciation...
Fire
specific
information
at a
glance!
Especially
designed
for
fire
systems,
the
PC4612
complements
the
use
of
standard
PC4632/
PC4664
annunciators,
which
may
be
used
on
the
same
fire
system,
by
adding
specific
annunciation
for
fire
alarm
zones,
fire
supervisory
zones,
and
fire
troubles. |
|
|
|
|
|
|
|
| |
|
PC4010CF / PC4020CF...
with UL864
Commercial Fire
listings… plus…all
the features of
MAXSYS security
systems!
Take a MAXSYS
security system with
fire savvy software
and specially
engineered fire
application
hardware, and not
only do you have a
great security
system, you also
have a powerful fire
alarm system.
|
| |
|
PC4702BP Dual Bell
Output Panel…
Complete with
integral transformer
and battery charger,
the PC4702BP
connects to the
COMBUS wherever
required to provide
audible & visual
fire alarm
notification zones.
With up to 4 panels
per system, 8 zones
total, and each zone
providing 1.8 Amps
at 24 VDC, MAXSYS
solves the power
issues for fire
alarm strobes and
horns. |
| |
Addressable Smoke
detectors...
Use addressable
loops to add up to
56 DSC UL/ ULC
listed addressable
smoke detectors on
PC4010CF systems and
112 on PC4020CF
systems to meet the
needs of large
applications
efficiently and
economically.
|
| |
Universal Remote
Zone expansion...
Use any mix of
listed security and
fire alarm detectors
on the same zone
expanders as the
MAXSYS security
system. Commercial
Fire zones can be
standard fire, water
flow, auto-verify
fire, and fire
supervisory.
|
|
| |
 |
| |
|
Fire keypads...
MAXSYS has a full
line of fire keypads
with all the
features of MAXSYS
security keypads
plus red bezels and
special Fire System
defaults for the 5
function keys
including :
-
Silence Trouble
-
Silence Bells
-
Fire Reset
-
Fire Drill
-
Lamp Test
|
| |
PS4350R External
Battery Charger…
Complete with
integral
transformer, the
PS4350R provides the
large capacity
battery backup power
supply required by
commercial fire
alarm systems. |
| |
|
|
|
|
|
Special
Software
Features
for
Fire…
Alarm
Auto-Scroll…displays
fire
alarms
and
selected
fire
troubles
at
two
second
intervals
on
all
system
keypads.
Fire
Drill…user-initiated
for
easy
evacuation
drills.
Fire
Inspector's
Test…simplifies
system
verification
testing.
Auto-Verify…programmable
by
zone
for
2-wire,
4-wire
and
addressable
smoke
detector
zones.
Waterflow
Delay…programmable
timer
for
waterflow
zones.
Fire
Silence
Inhibit…prevent
manual
signal
silence
for
a
programmable
time
period.
Synchronized
Temporal
Pattern…automatic
synchronized
audible
alarm
notification
for
zones
programmed
with
the
temporal
pattern. |
|
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
 |
|
|
| |
|
PC4820 Dual Reader
Access Control...
integrates
Access Control with
MAXSYS fire and
security systems for
single system
responsibility! |
|
|
|
| |
| Features |
| · |
up to 16 dual reader panels for 32 readers per system |
| · |
full standalone operation… complete card database & all programming is maintained in the PC4820's non-volatile memory |
| · |
arm/ disarm partitions & postpone autoarm by access card or access card and code…from outside the protected space |
| · |
64 access levels |
| · |
99 seven-day schedules |
| · |
4 two year holiday groups - 730 holidays |
| · |
individual door unlock schedules |
| · |
automatic switching between daylight savings & standard time |
| · |
program via keypad, or via computer with DLS-2 upload/download software |
|
|
|
|
|
|
 |
|
|
|
Escort4580 Voice Assisted
Security and Automation
Control Module…
The Escort4580 operates in
conjunction with any
touch-tone telephone to
provide an easy to
understand plain language
interface for MAXSYS
Security Systems. Escort
allows the telephone to be
used as a keypad while
providing the user with
operational and programming
voice prompts as well as
plain language system status
reports. In addition, Escort
acts as an interface for up
to thirty two X-10
automation control devices
complete with voice assisted
operation and programming. |
|
PC4400 Printer or
DVACS Output module…
Use as a true RS-232 serial
interface to a serial
printer and receive
comprehensive management
information reports from
MAXSYS' 3,000 event buffer
or, in Canada, optionally
use the PC4400 as a DVACS
interface to take advantage
of available high security
DVACS communications
networks. |
Systems Integrator ... Consultant
... Contractor
As systems integrator, initially we
will act as consultant for our
client. We will review the needs of
our client's organization, compare
them with the products, features,
and options available, and then
evaluate how they can be put to work
to meet our client's needs.
After identifying a course of
action, we will schedule and perform
the necessary installation and
training. During installation, we
will ensure that any legacy systems
are integrated with the new systems
so that both will interoperate
seamlessly and transparently.
During training we will make sure
that our client has a complete
understanding of the system and how
to use it for maximum productivity.
In the years after installation,
BTS will work with our clients
as they grow. We adjust and
fine-tune their business systems as
their needs adjust. We will work
diligently to ensure the reliability
of their systems. It is our job to
guarantee a long and trouble-free
life for any business system that we
install or maintain. Fortunately,
we only use the highest quality
products, installed by manufacturer
certified installers, that last a
lifetime. That makes our job much
easier.
Lifelong Partnership ...
Our goal is to
develop a relationship with our
customers that will last a
lifetime. We will make ourselves
available to assist our clients in
any way we can, for any problem they
might have. As a client, when you
don't know who to turn to, we want
to be there for you. We might not
always have the answer, but we will
certainly assist you in finding
someone who does. We want to see
your company succeed for many years
to come so that we will have one
more satisfied customer out there
telling people about the quality and
reliability of Business
Technology Systems.
top
|
|